Project:Membrane Reactor System

Client: : Indian Institute of Technology, Kharagpur

Technical Specifications

In October 2007, Texol completed the project for the Membrane Reactor System, IIT Kharagpur. This unit used to test membrane developed for separation of Hydrogen from the mixture of gas at the outlet of reformer.

Reactor is designed to operate at 5 bar g at 550 Deg C.

Important process parameters like gas flow; liquid flow & reactor temperature are controlled using Single loop control system.